Detector
¡¡ DAP31-33 Protable Combustible Gas Detector new!
¡¡ DTQB-518 Explosion-Prevention Combustible Gas Detector
¡¡ DAP31-12L Dot Type Combustible Gas Detector
¡¡ QB-DAP32-12LC Explosion-insulated Toxic Gas Detector
¡¡ DAP31-21X1 Combustible Gas Detector
¡¡ DAP31-21B Free-standing Combustible Gas Alarm Device
¡¡ DAP3200 Heat Detector For Fixed Temperature
¡¡ DAP3210 Anti-Explosion Rate-of-rise and Fixed Temperature Detector
¡¡ DAP3300 Analogue Photoelectric Smoke Detector -
¡¡ DAP3620 Intelligent Digital Heat Detector for Fixed Temperature
¡¡ DAP3600 Intelligent Digital Optical Smoke Detector
¡¡ DAP3000 Hand Alarm Button
¡¡ DAP3000 Anti-Explosion Hand Alarm Button
¡¡ DAP5000 Annunciator for Sound and Light
¡¡ DAP5010 Alarming Indicator Light
¡¡ DAP5020 Fire Fighting Alarm Bell

Camera (click here)

System
¡¡ DAP2102-GB1 Combusitle Gas Alarming Controller new!
¡¡ Computer Surveillance System For Combustible Gas Concentration new!
¡¡ DAP2102GP1-BUILT-IN COMBUSTIBLE GAS ALARM SYSTEM
¡¡ QB-DAP2000 TRAY TYPE COMBUSTIBLE GAS ALARM SYSTEM
¡¡ QB-DAP2000 WALL MOUNTING COMBUSTIBLE GAS ALARM SYSTEM
¡¡ QB-DAP2103-GB64 COMBUSTIBLE GAS ALARM SYSTEM
¡¡ QB-DAP2103-GB64 ON-OFF COMBUSTIBLE GAS ALARM SYSTEM--With BUS System¡¡
¡¡ DAP-2006A Network Intelligent Alarm System
¡¡ Introduction to GPS Intelligent Information Platform

¡¡ Use HG2116-600 series DVR as the core of the simulate/digital synthetic security defense system



DAP2102£­GP1 BUILT-IN COMBUSTIBLE GAS ALARM SYSTEM
1 General Description
DAP2102£­GP1 built-in combustible gas alarm system is an intelligent system. It consists of DAP2102£­GP1 alarm controller and DTQB-518 combustible gas sensor with explosion prevention performance.
The Sensor is installed at area where the potentially explosive atmosphere may be detected. It will send out a signal that is positive proportion with the concentration of combustible gas while the sensor touches combustible gas in air. Alarm controller will loop-show each detector¡¯s low-limited percent of L.E.L as well as send out an audible/visual alarm and control signal that hints operator to either take countermeasure or control relational automatic safe device while the value of concentration gets to preset alarm value. It may ensure safe work and avoid explosive accident.

2 Detected Gas
All types of Hydrocarbon combustible gas, including: hydrogen, natural gas, coal gas, liquid gas, jet fuel, gasoline, alkyl, alkene genus, alkone ketone genus, methanol, ethanol, aether genus, benzene genus etc.

3 Characteristic
1 Sensor can be remote mounted and demarcated (option install) installation flexibility and safety
2 Warning, alarm & fault relays Provides local alarm capability
3 Calibration, calibration check, setup mode Simplifies operation and maintenance
4 Tray type , Modular, plug-in signal input cards System expandability, simplified maintenance
5 Sensor adopts 3-wire connection system
6 Auto-checking
7 Key lock function
8 Sensor can resist 200ppm sulfureted hydrogen gas (must be noted on order form)
9 Locale concentration display on sensor (option install)
10 Sensor invalidation display on site (option install)
11 Alarm controller acts on high-limited and low-limited and send out a controlling signal.
12 RS-485 micro-processor
13 Figure and light beam alarming level display

4 Major Performance and Specifications

Sensor

Explosion prevention level

dIICT6

Detecting principle

catalytic combustion

Out put

4~20mA standard signal

Indication error

¡À 3% £¨ F.S £©

Working voltage

DC24V ¡À 15%

Working current

55mA

Display mode

digital LED (option install)

Working temperature

-40 ¡æ ~ 70 ¡æ

Working humidity

¡Ü 95%RH

Transmission resistance

£µ£°¦¸

Weight

1Kg

Structure dimension

90¡Á85¡Á 110mm

Calibration gas

CH4, i-C4H10


Alarm controller

Detecting range

0~100%LEL

Carried detector number

1 to 4 detectors

Concentration display

LCD display

Working voltage

AC220V

Standby power supply

24V, 4AH (storage battery choosed by user)

Working temperature

0 ¡æ ~ 40 ¡æ

Working humidity

¡Ü 95%

Transmission distance

¡Ü 2Km

Response time

¡Ü 30S

Weight

5Kg

Structure dimensions

270¡Á248¡Á 135mm

Contact output

2 groups in hi-limited for each card, Long-time andcontinuous detecting

Communication

RS-485

 

5 Sensor structure dimension and installation:
The sensor consists of an aluminum alloy shell and stainless steel components (the dimension of the hole for wire: M20¡Á1.5 or G1/2 inch).

6 Alarm controller structure and mounting hole dimension:

7 Connection sketch map:
W¡¢O¡¢B ends of sensor is connection point of the sensor.
I¡¢+24V- ends of sensor should be separately connected with I¡¢+24V- on back panel of the alarm controller.


QB £­ DAP2000 TRAY TYPE COMBUSTIBLE GAS ALARM SYSTEM
1 General Description
QB£­DAP2000 tray type combustible gas alarm system is an intelligent alarm system, consisting of QB£­DAP2000 alarm controller and DTQB-518 combustible gas sensor with explosion prevention performance.
The Sensor is installed at the area where combustible gas may be leaked. It will send out a signal that is positive proportion with the concentration of combustible gas while the sensor touches combustible gas in air. Alarm controller will loop-show each detector's low-limited percent of L.E.L as well as send out an audible/visual alarm and control signal that hints operator to either take countermeasure or control relational automatic safe device while the value of concentration gets to preset alarm value. It may ensure safe work and avoid explosive accident.
2 Detected Gas
All types of Hydrocarbon combustible gas, including: hydrogen, natural gas, city coal gas, liquid gas, jet fuel, gasoline, alkyl, alkene genus, alkone ketone genus, methanol, ethanol, aether genus, benzene genus etc.

3 Characteristic
14 Tray type , Modular, plug-in signal input cards System expandability, simplified maintenance
15 Sensor adopts 3-wire connection system
16 Sensor can resist 200ppm sulfureted hydrogen gas (must be noted on order form)
17 Alarm controller acts on high-limited and low-limited and send out controlling signal.
18 Enactment alarming value on site
19 Dark casket function
20 Auto-checking
21 Warning, alarm & fault relays Provides local alarm capability
22 Key lock function
23 Locale concentration display on sensor (option install)
24 Sensor can be remote mounted and demarcated (option install) installation flexibility and safety
25 Sensor invalidation display on site (option install)
26 Calibration, calibration check, setup mode Simplifies operation and maintenance

4 Major Performance and Specifications

Sensor

Explosion prevention level

dIICT6

Detecting principle

catalytic combustion

Out put

4~20mA standard signal

Indication error

¡À 3% £¨ F.S £©

Working voltage

DC24V ¡À 15%

Working current

55mA

Display mode

digital LCD (option install)

Working temperature

-40 ¡æ ~ 70 ¡æ

Working humidity

¡Ü 95%RH

Transmission resistance

£µ£°¦¸

Weight

1Kg

Structure dimensions

90¡Á85¡Á 110mm

Calibration gas

CH4, i-C4H10


Alarm controller

Detecting range

0~100%LEL

Carried detector number

8 detectors (MAX)

Working voltage

AC220V

Standby power supply

24V, 4AH (storage battery option)

Power consumption

60W

Working temperature

0 ¡æ ~ 40 ¡æ

Working humidity

¡Ü 95%

Transmission distance

¡Ü 2Km

Response time

¡Ü 30S

Weight

10Kg

Structure dimensions

160¡Á160¡Á 350mm

Contact output

2 sets in hi-limited, 8 sets in low-limited. Long-time and continuous detecting


5 Sensor structure dimension and install:
The sensor consists of an aluminum alloy shell and stainless steel components (the dimension of the hole for wire: M20¡Á1.5 or G1/2 inch).

6 Alarm controller structure and mounting hole dimension:

7 Connection sketch map:
W¡¢O¡¢B ends of sensor is connection point of the sensor.
I¡¢+24V- ends of sensor should be separately connected with I¡¢+24V- on back panel of the alarm controller.


QB-DAP2000 WALL MOUNTING COMBUSTIBLE GAS ALARM SYSTEM
1 General Description
QB£­DAP2000 wall mounting combustible gas alarm system is an intelligent alarm system, consisting of QB£­DAP2000 alarm controller and DTQB-518 combustible gas sensor with explosion prevention performance.
The Sensor is installed at the area where combustible gas may be leaked. The sensor will send out a signal that is positive proportion with the concentration of combustible gas while the sensor touches combustible gas in air. Alarm controller will loop-show each detector¡¯s low-limited percent of L.E.L as well as send out an audible/visual alarm and control signal that hints operator to either take countermeasure or control relational automatic safe device while the value of concentration gets to preset alarm value. It may ensure safe work and avoid explosive accident.
2 Detected Gas
All types of Hydrocarbon combustible gas, including: hydrogen, natural gas, city coal gas, liquid gas, jet fuel, gasoline, alkyl, alkene genus, alkone ketone genus, methanol, ethanol, aether genus, benzene genus etc.

3 Characteristic
1 Sensor can resist 200ppm sulfureted hydrogen gas (must be noted on order form)
2 Alarm controller acts on high-limited and low-limited and send out controlling signal.
3 Enactment alarming value on site
4 Dark casket function
5 Auto-checking
6 Warning, alarm & fault relays Provides local alarm capability
7 Key lock function
8 Wall mounting for alarm controller
9 Sensor adopts 4-wire connection system
10 Locale concentration loop-display on sensor

4 Major Performance and Specifications

Detector

Detecting principle

catalytic combustion

Explosion prevention level

dIICT6

Out put

DC voltage

Indication error

¡À 3% £¨ F.S £©

Working voltage

DC24V ¡À 15%

Working current

50mA

Working temperature

-40 ¡æ ~ 70 ¡æ

Working humidity

¡Ü 95%RH

Detection radius

5 ~ 6m

Connection mode

4-wire system

Calibration gas

CH4, i-C4H10


Alarm controller

Detecting range

0~100%LEL

Alarming register

yes

Concentration display

LCD display

Working voltage

AC220V

Standby power supply

24V, 2AH or 4AH (storage battery option)

Power consumption

¡Ü 60W

Working temperature

0 ¡æ ~ 40 ¡æ

Working humidity

¡Ü 95%

Transmission distance

¡Ü 1Km

Response time

¡Ü 30S

Weight

10Kg

Carried detector number

2, 4, or 8 detectors

Contact output

hi-limited, low-limited. Long-term and continuous detecting

Alarm setting

2 grades alarm. Adjustable Setting point

5 Sensor structure dimension and install:
The sensor consists of an aluminum alloy shell and stainless steel components (the dimension of the hole for wire: M20¡Á1.5 or G1/2 inch).

6 Alarm controller structure and mounting hole dimension:

7 Connection sketch map:
W¡¢O¡¢B ends of sensor is connection point of the sensor.
U+¡¢U-¡¢+24V- ends of sensor should be separately connected with U+¡¢U-¡¢+24V- ends board of the alarm controller.


QB-DAP2103-GB64 COMBUSTIBLE GAS ALARM SYSTEM
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡--With 4-wire BUS, LCD Concentration Data Display
1 General Description
QB-DAP2103-GB64 combustible gas alarm system is a 4-wire BUS alarm system, consisting of QB-DAP2103-GB64 alarm controller and QB-DAP31-12L combustible gas detector with explosion prevention performance.
The detector is installed at area where the potentially explosive atmosphere may be detected. The detector will send out a signal to alarm controller, which is positive proportion with the concentration of combustible gas while the sensor touches combustible gas in air. Alarm controller will loop-show each detector¡¯s low-limited percent of L.E.L as well as send out an audible/visual alarm and control signal that hints operator to either take countermeasure or control relational automatic safe device while the value of concentration gets to preset alarm value. It may ensure safe work and avoid explosive accident.
2 Detected Gas
All types of Hydrocarbon combustible gas, including: hydrogen, natural gas, city coal gas, liquid gas, jet fuel, gasoline, alkyl, alkene genus, alkone ketone genus, methanol, ethanol, aether genus, benzene genus etc.

3 Characteristic
11 Detector addresses can be coded on site
12 Sensor can resist 200ppm sulfureted hydrogen gas (must be noted on order form)
13 LCD display concentration
14 RS-485 standard port
15 Tracking alarm record and fault alarming
16 Standby power
17 Explosion prevention output module, link action on site
18 4-wire BUS mounting
19 Insulator to divide detectors

4 Major Performance and Specifications

Detector

Detecting principle

catalytic combustion

Explosion prevention level

dIICT6

Working voltage

DC24V ¡À 15%

Working current

35mA

working temperature

-40 ¡æ ~ 70 ¡æ

Working humidity

¡Ü 95%RH

Detecting radius

5~ 6m

Calibration gas

CH4, i-C4H10


Alarm controller

Detecting range

0~100%LEL

Alarming register

yes

Concentration indication

LCD indicator

Alarm setting

2 alarming grades. Adjustable Setting point

High-limited alarming

50%LEL (Adjustable Setting)

Low- limited alarming

25%LEL (Adjustable Setting)

Indication error

¡Ü 3%LEL

Working temperature

0 ¡æ ~ 40 ¡æ

Working voltage

AC 220V

Response time

¡Ü 30S

Transmission distance

¡Ü 1Km

Carried detector number

16, 32, or 64 detectors

Contact output

16 groups Long-term and continuous detecting (contact capability is 220V, 2A )

Standby power supply

24V, 1.3AH

30V, 6AH(detector)

5 Sensor structure dimension and install:
The sensor consists of an aluminum alloy shell and stainless steel components (the dimension of the hole for wire: M20¡Á1.5 or G1/2 inch).

6 Alarm controller structure and hole dimension:

7 Connection sketch map:
W¡¢O¡¢B ends of sensor is connection point of the sensor.
L+¡¢L-¡¢+24V- ends of detector should be connected with the end board of alarm controller through BUS.


QB-DAP2103-GB64 ON-OFF COMBUSTIBLE GAS ALARM SYSTEM
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡--With BUS System
1. General Description
QB-DAP2103-GB64 combustible gas alarm system is a 4-wire BUS alarm system, consisting of QB-DAP2103-GB64 alarm controller, DAP31-121 combustible gas detector and QB-DAP31-12L on-off combustible gas detector with explosion prevention performance.
The detector is installed at area where the potentially explosive atmosphere may be detected. The detector will send out a signal to alarm controller, which is positive proportion with the concentration of combustible gas while the sensor touches combustible gas in air. Alarm controller will send out an audible/visual alarm and control signal that hints operator to either take countermeasure or control relational automatic safe device while the value of concentration gets to preset alarm value. It may ensure safe work and avoid explosive accident.

2. Detected Gas
All types of Hydrocarbon combustible gas, including: hydrogen, natural gas, city coal gas, liquid gas, jet fuel, gasoline, alkyl, alkene genus, alkone ketone genus, methanol, ethanol, aether genus, benzene genus etc.

3. Characteristic
20 4-wire BUS connection, 2 lines for power BUS, 2 lines for signal BUS.
21 Large capacity, enough applied to great engineering
22 Large screen LCD display, more information, friendship interface
23 Wall mounting
24 Tracking alarm record and fault alarming
25 Both non-preventive explosive and preventive explosive combustible gas detectors in the system
26 Programming on site

4. Major Performance and Specifications

Detector

Detecting principle

catalytic combustion

Explosion prevention level

dIICT6

Working voltage

DC24V ¡À 15%

Working current

35mA

Working temperature

-40 ¡æ ~ 70 ¡æ

Working humidity

¡Ü 95%RH

Detecting radius

5 ~ 6m

Calibration gas

CH4, i-C4H10


Alarm controller

Detecting range

0~100%LEL

Alarming register

yes

Concentration indication

LCD indicator

Alarm setting

2 alarming grades. Adjustable Setting point

High-limited alarming

50%LEL (Adjustable Setting)

Low- limited alarming

25%LEL (Adjustable Setting)

Indication error

¡Ü 3%LEL

Working temperature

0 ¡æ ~ 40 ¡æ

Working voltage

AC 220V

Response time

¡Ü 30S

Transmission distance

¡Ü 1Km

Carried detector number

16, 32, or 64 detectors

Contact output

16 groups Long-time and continuous detecting (contact capability is 220V, 2A )

Standby power supply

24V, 1.3AH

30V, 6AH(detector)

5 Sensor structure dimension and install:
The sensor consists of an aluminum alloy shell and stainless steel components (the dimension of the hole for wire: M20¡Á1.5 or G1/2 inch).

6 Alarm controller structure and hole dimension:

7 Connection sketch map:
W¡¢O¡¢B ends of sensor is connection point of the sensor.
L+¡¢L-¡¢+24V- ends of detector should be connected with the end board of alarm controller through BUS.

 

 

£ºinfo@dap.com.cn¡¡¡¡¡¡  £º(0086)010-62141373 ¡¡
Copyright©BEIJING DEPENDABLE TECHNOLOGY & SCIENCE DEVELOPMENT Co.£¬ Ltd. All Rights Reserved